SPECIFICATIONS
General Specification of all our Developments – we can offer a more bespoke development
Asbestos
-
Asbestos should not be present in the building.
Adaptations
-
There should be options to allow for adaptations to be made depending on the needs of the tenants.
Bathrooms
-
Preference for shower screens (subject to CP/commissioner preference).
-
No saniflow systems are to be installed.
Blinds
-
Blinds/window coverings should be provided to all windows.
​
Communal Furniture
-
Furniture should be provided for communal areas – specification to be determined by needs of tenants.
​
Furniture For Personal Use
-
Furniture packs (or sum) should be provided to allow units to be fully furnished (subject to budget and commissioner preference).
​
Communal Space
-
Subject to client group/commissioner preference - enough space should be provided to allow for kitchenette, table and seating.
-
A separate bathroom with shower should be provided on the ground floor for use in emergency.
Decoration
-
Neutral decoration – greys/whites.
-
Non-slip flooring in bathrooms.
-
Waterproof flooring in kitchen areas.
Energy Efficiency
-
Minimum EPC Rating: C.
Facilities
-
Communal WC to be provided for staff, visitors and tenants.
Fire
-
Fire doors should provide 60-minute compartmentation to each unit.
-
Intumescent cold smoke seals to be included.
-
Door closers should be installed on all fire doors.
-
Means of escape for all habitable rooms.
-
Fire system should be to BS5839 Part 6 Grade A LD1.
-
Emergency lighting system to meet fire strategy.
-
Electricity supplies to automatic fire detection and alarm systems and emergency lighting shall be from a landlord’s supply.
-
Properly mounted fire blanket - kitchens.
-
Heat detector in kitchens.
-
All signage for escape, fire safety and health and safety must be provided in line with FRA and fire strategy for the building and be in place at handover.
Heating/Hot Water
-
New boilers.
-
Low surface temperature radiators to be provided if required (subject to CP requirements/client group risks).
-
TMVs to be fitted to water outlets.
-
Cylinder immersions must be provided on all hot water and storage cylinders.
-
Standard boilers and water heating systems should be provided (Bosch etc) – units should be repairable by any boiler engineer.
Fireplaces
-
No gas fires to be present.
-
All open fireplaces should be adequately blocked to prevent use and vented.
​
Intercom System
-
Intercom connection from reception to bedroom areas/flats should be provided – agreed to specification of care provider/commissioner.
Kitchens
Appliances to be provided (should be energy efficient appliances rated A or B):
-
Cooker.
-
Induction Hob.
-
60/40 Fridge-Freezer.
-
Washing Machine.
-
Extractor Hood.
Recommended manufacturers: Neff, Bosch, Miele, Whirlpool, Samsung, LG.
Electric preferred.
No gas cookers.
Layout of Dwellings
-
No bedroom should lead directly off the kitchen or kitchen/diner.
-
Bedrooms must open onto a landing or hallway i.e. they cannot be accessed by going through another room unless an approved alternative escape is provided.
Lighting
-
No fluorescent lighting (only acceptable in the kitchen subject to prior approval).
-
The bathroom should have a ceiling pull switch.
-
External lights for pathways, decking, patio, entrance doors – connected to landlord supply.
-
Sensor lights to be provided in hallways.
Location
-
Safe areas with good transport links, adequate street lighting close to shops, cafes, community centres, parks etc.
Noise
-
Effective sound insulation should be provided.
Office
-
Space to allow for a staff ‘hub’, safe storage of files and for confidential meetings to take place.
Outside Space
-
Designated area for smoking – open-sided cover to be provided with non-flammable flooring.
Fences
-
Boundary fences to be provided – agreed with CP/Commissioners.
Parking
-
Adequate parking spaces for tenants / staff and visitors should be provided wherever possible.
Refuse Disposal
-
Adequate bin store to be provided where required.
Security
-
Final exit doors from building should release on sounding of fire alarm
-
Fob/Secure access to exit/entrance doors to building
-
Key pad locks to gates
-
Thumb-turn releases to all apartment exit doors and final exits from building
-
A CCTV system should be provided that links to a central monitor located in the staff area. The monitor should allow staff to zoom in.
-
Burglar alarms where fitted will have a 20-minute cut out and a nominated key holder
-
Each flat shall be provided with a lockable post box situated on the ground floor in a lobby or hallway accessible to the postal delivery service (unless the flat has its own front door accessible directly from the exterior)
Sizes
-
As per the Technical housing standards – nationally described space standard:
*Where a 1b1p has a shower room instead of a bathroom, the floor area may be reduced from 39m2 to 37m2, as shown bracketed.
​
Sockets
-
Location/number to be agreed per layout of rooms.
-
A separate fused spur outlet for the cooker should be provided.
Structure of Premises
-
A full condition/structural survey should be provided – any structural works deemed to be necessary during the term of the proposed lease must be renewed/resolved e.g. roof.
-
There must be no evidence of leaks or damage to the soil or waste pipes and seals at ground level must be good.
-
Inspection chamber covers must be accessible, in good condition and easily removable for maintenance.
-
The Council may require the landlord to carry out a drain survey (including underground drains) if there is any doubt about the condition of the drains.
Utilities
-
Each dwelling must have its own electricity, gas and water meter.
-
Isolation points are required with stopcocks and switches clearly labelled, easy to reach and accessibly located within each property.
-
The meters should ideally be in one location outside of individual dwellings for easy access. The location must be lockable.
-
Electricity meters and fuse boards and gas meters located on escape routes, such as fire exits, stairs or communal hallways need to be located in a fireproof cupboard and the latter should also be vented to the exterior.
Gas
-
Co3 monitors should be fitted as per guidance.
Windows
-
Must be double-glazed as a minimum.
-
must be fitted with window restrictors.
-
Glazing/frosting should be provided in bathroom windows for privacy.
​